65 800 000 сум
Технические характеристики
| Quvvat transformatorlarining parametrlarini o'lchash uchun qurilmaning texnik tavsifi Koeffitsient: | |
| O'lchov miqdori Belgilanishi O'lchov diapazoni Ruxsat etilgan asosiy o'lchov xatosi, % | |
| O'zgaruvchan kuchlanishning samarali (rms) qiymati (U), V U 25-400 ±[0,5+0,05·(Uk/U-1)] | |
| O'zgaruvchan kuchlanishning samarali (rms) qiymati (Unnn), V Unn1 42-420 ±[0,5+0,05·(Unnn1k/Unnn1-1)] | |
| Unn2 | 2-42 ±[0,5+0,05·(Unn2k/Unn2-1)] |
| Transformatsiya koeffitsienti (Kt) Kt1 UV/ Unn1 ±[0,5+0,05·(Kt1/Kt1n-1)] | |
| Kt2 UV/ Unn2 ±[0,5+0,05·(Kt2/Kt2n-1)] | |
| O'zgaruvchan tokning samarali (rms) qiymati (I), A I0 20-100 ±[2+0,2·(I0k/I0-1)] | |
| I1 2,0-20 ±[0,5+0,05·(I1k/I1-1)] | |
| I2 0,20-2,0 ±[0,5+0,05·(I2k/I2-1)] | |
| I3 0,020-0,20 ±[1+0,2·(I3k/I3-1)] | |
| Past kuchlanishdagi yuksiz yo'qotishlar (faol elektr quvvati) (cos=1,0), W P11 I1·UV ±[0,5+0,05·(P11k/P11-1)] | |
| P21 I2·UV ±[0,5+0,05·(P21k/P21-1)] | |
| P31 I3·UV ±[1+0,2·(P31k/P31-1)] | |
| Past kuchlanishdagi yuksiz yo'qotishlar (faol elektr quvvati) (cos=0,5), W P12 I1·UV ±[1+0,1·(P12k/P12-1)] | |
| P22 I2·UV ±[1+0,1·(P22k/P22-1)] | |
| P32 I3·UV ±[1+0,1·(P32k/P32-1)] | |
| Qisqa tutashuvga qarshilik (Zkz), Ohm Zkz3 UV/ I3 ±[1+0,1·(Zkz3/Zkz3n-1)] | |
| Zkz2 UV/ I2 ±[0,5+0,05·(Zkz2/Zkz2n-1)] | |
| Zkz1 UV/ I1 ±[0,5+0,05·(Zkz1/Zkz1n-1)] | |
| Zkz0 UV/ I0 ±[2+0,2·(Zkz0/Zkz0n-1)] | |
| Ko'rsatilgan natijalar: oqim, kuchlanish va qarshilik | |
| Besleme zo'riqishida faza | 220 V yoki chiziqli 380 V |
| Ishlash harorati oralig'i | -5 dan +40 ° C gacha |
| Qurilmaning og'irligi (penssiz) | 5 kg |